ROBOTAPE 50 CFA
3.3. SAFETY DEVICE DESCRIPTIONS
The figure shows the positioning of the devices on board of the machine.
A-A1)
Main disconnecting switch (lockable): used to activate and deactivate the machine's electrical power
supply.
It comes with a padlock to prevent unauthorised personnel from activating the power supply.
B)
Emergency button; the machine stops immediately when this button is pressed in emergency
situations.
To reset, rotate the button in the direction indicated by the arrow.
C)
Fixed guard: outside structure which prevents the operator accessing.
D-E)
Interlocked mobile guard: allows the operator to access the interior of the operating area.
It is a door associated with an electric interlock device. Upon opening the machine stops immediately.
Its restart is only possible upon closing of the door and restoring of the cycle.
F)
General exhaust solenoid valve: closes the compressed air inlet line when the machine is not electrically
powered or when it is stopped in emergency conditions.
G)
General disconnecting switch (can be padlocked): used to activate and deactivate the pneumatic
supply. Can be padlocked and prevents the pneumatic activation by unauthorised persons.
English