ROBOTAPE 50 CFA
TAPE CLOSING OR
DESCENDING BRIDGE
PHOTOCELL ALARMS
ENGAGED
The tape closure
or bridge
descending
photocell is
engaged
immediately after
the bridge rises
up again and the
belts are
reopened.
Red light: 1
flash.
- Remove any
products found in
front of the
photocells.
- Press the "Start"
button.
PRODUCT TRANSIT
WARNING
A product is
taking too long
to be taped.
Red light: 2
flashes.
- Press the "STOP"
button.
- Remove the
product.
- Press the "Start"
button.
BRIDGE NOT UP
WARNING
The bridge can’t
reach the upward
position.
Red light: 3
flashes.
- Check the
pressure in the
pneumatic system.
- Press the "Start"
button.
TAPES NOT OPEN
WARNING
The tapes are not
opening.
Red light: 4
flashes.
- Check the
pressure in the
pneumatic system.
- Press the "Start"
button.
BRIDGE NOT DOWN
WARNING
The bridge can’t
reach the
downward
position.
Red light: 5
flashes.
- Press the "STOP"
button.
- Check the
pressure in the
pneumatic system.
- Press the "Start"
button.
FLAP COVER
PHOTOCELL ALARM
ENGAGED
The flap closure
photocell doesn’t
free itself
during the taping
of the product.
Red light: 6
flashes.
- Press the "STOP"
button.
- Remove the
products.
Press the "Start"
button -.
ENTRANCE
PHOTOCELL ALARM
ENGAGED
The flap closure
photocell or the
entrance
photocell are
engaged for too
long while
waiting for
products: a
product may be
stuck in the
entrance.
Red light: 7
flashes.
- Press the "STOP"
button.
- Remove the
products.
- Press the "Start"
button.
8.3. MESSAGES
|
Note
These messages do not stop the machine.
English
52/75