27
STANDARDS
Consult the declaration of compliance on page 2.
Display
Description
Action to take
Er04
Inconsistent configu-
ration
Dismantle and assemble all
accessories; press on the Stop
Switch to reset
Er05
Internal bus over-
voltage
Check the machine’s power
supply
Er06
Thermal cut-out control
board
Allow the appliance to cool
down; press on the Stop Switch
to reset
Er07
Checking bowl safety
Remove the bowl then replace
it to reset the safety features.
Other
message
Contact your After-Sales
Service
Display
Description
Action to take
Er01
Thermal variator
cut-out
Allow the machine to cool
down; press on the Stop switch
to reset
Er02
Thermal motor cut-out Allow the machine to cool
down; run faster or use the
intermittent function 0101
Er03
Power supply
Check the machine’s power
supply
R E M E N B E R
Never try to override the locking and safety
systems.
Never introduce any object into the container
where the food is being processed.
Never push the ingredients down with your
hand.
Do not overload the appliance
OPERATION ERRORS
Your Robot Cook
®
has a function which enables it to
display the different causes of possible errors.
Depending on the message displayed, you will be
aware of the nature of the error, and of possible
solutions.
See the table opposite.
• LIST OF ERRORS DISPLAYED