background image

Here are feature comparisons between the 

Bus-Scan

®

 CR2

 and the CRS CR2 A/B:

Function

Bus-Scan

®

 CR2

CRS CR2 A/

B

Ignition 

ON

 (12V) Prepares the system for operation.

YES

YES

Arming Signal (12V) Arms the system 

OR

...

YES

YES

System will automatically 

ARM

 after 10 minutes w/door(s) closed.

YES

YES

System has 2 door-sensing inputs: One for +12V / One for 0V (Gnd)

YES

YES

If either the White or Blk/Gry Wire is Grounded (0V), the system will

DISARM

, and the interior lights will flash twice to confirm.

YES

YES

If Exit Courtesy Lights are on, they can be interrupted by turning 

the Ignition 

ON

, so that the system is immediately ready for 

operation.

YES

NO

If the system has been 

ARMED

, then the Ignition is turned off, a 

reminder tone will sound, indicating that the vehicle must be 
checked & disarmed.  Also, the dome lights will be activated.

YES

YES

Ignition must be in the 

OFF

 position to disarm system.

YES

YES

If any door is opened during the 

REMINDER

 state, the horn will 

ALARM

— ½ second on / ½ second off intervals until system is 

disarmed.

YES

YES

Ignored Horn Fail-safe operation:  An ignored Horn alarm will cease 

sounding after 5 minutes, to save battery power and horn function.

YES

NO

If the system is in an 

ALARM

 state, the only way to stop the alarm 

is to recycle the ignition and start the 

DISARM/INSPECTION

 

sequence over.  The system will not permit an exit without alarm 
until the proper 

DISARM SEQUENCE 

has been performed.

YES

YES

Upon 

DISARM

, the interior lights will remain 

ON

 for a period of 60 

seconds, for help in exiting the vehicle (Exit Courtesy Lights).

YES

YES

Entry Courtesy Lights will be activated for 60 seconds upon first 
entry (door open, if closed / door closed, if open).  Activating 

Ignition will cancel the lights.

YES

NO

If Ignition is 

ON

 and a door is opened, Passenger Courtesy Lights 

will be activated to help guide passengers on/off the vehicle.  The 

lights will be immediately turned 

OFF

 upon door closing.

YES

NO

The Warning Beeper is built-in, so no additional wiring is required.

YES

NO

Dual-row, 6-position Interface Connector for Power & Signals

YES

YES

Single-row 2-position Interface Connector for Remote LED

YES

YES

NOTE:  We have been told that the main connector in the CRS CR2 A/B was too accessible, and 
was being disconnected by some drivers.  We have purposely recessed the connector slightly, to 

make that less likely.  Please let us know if that helps.

More features have been created for the 

Bus-Scan

®

 CR2. See the next page for 

details.

Reviews: