background image

New CR2 Features

3-Position DIP Switch on Back of Unit

1. Timed Auto-arming

 (field-trip mode).  In addition to arming the Bus-Scan 

CR2

 

by an input signal (8-way flashers, stop sign, etc.), you can choose to have the 
system automatically arm after the ignition has been on for 10 minutes, with both 

doors closed.  Enable by sliding 

Switch 1

 of the 3-position DIP switch to the 'ON' 

position.

2. Timed Alarm Mode 

Adds a timeout alarm to the usual “Door Opened Without 

Disarming” mode.  Sliding 

Switch 2

 to the 'ON' position enforces a time limit of 60

seconds for the driver to press the “Disarm” button.  Therefore, the system must 
be disarmed before opening a door AND within 60 seconds.

3. Diagnostic Mode 

 This is used for factory testing, but can be used during 

installation, to speed up the process.  There are many timed functions in the 

CR2

including auto-arming, light delays, etc.  Sliding 

Switch 3 

to the 'ON' position will 

“speed up the clock” to move through those delays very quickly—so that you can 

confirm that everything is working properly.  For example, the usual Auto-arm of 
10 minutes occurs in only 10 seconds.  If you use this special Diagnostic Mode, 

make sure to return 

 

 

Switch 3 

 

 to the 'OFF' position when you are finished.  

 

 

Otherwise, the system will not function properly.