2F-85 & 2F-140 - Instruction Manual
The gripper needs to be supplied by a DC voltage source. This power supply is not included with the gripper. Required power
supply must match the Robotiq device. The following table shows the specifications with regards to the power supply required to
operate the gripper and the optional Robotiq Controller.
SPECIFICATION
VALUE
Output voltage
24 V DC ±10%
Output current
1 A
Overcurrent
Recommended power supply with internal protection, otherwise fusing is
required.
2 A fuse at 25°C [77°F]
1
Table 3-1: 2-Finger power supply requirements.
Info
1
Suggested fuse is a: Phoenix Contact # 0916605 2 A thermal, use AWG #20 wiring.
Warning
If your power supply could exceed the specified regulation, over-voltage protection is required.
Robotiq recommends the use of the following power supplies:
l
For the 1A output current: TDK-Lambda DPP Series,
100W Single Output DIN Rail Mount Power Supply
: DPP30-24.
Tip
Optional Robotiq Universal Controller can use the same power supply.
18