2F-85 & 2F-140 - Instruction Manual
3.3. Environmental and Operating Conditions
CONDITION
VALUE
Minimum storage/transit
temperature
-30°C [-22°F]
Maximum storage/transit
temperature
70°C [158°F]
Minimum operating temperature
-10°C [14°F]
Maximum operating temperature
50°C [122°F]
Humidity (non-condensing)
20-80% RH
Maximum vibration
(storage/transit)
5G
Maximum vibration (operating)
2G
IP Rating
IP 40
Other
l
Free from dust, soot or fluids
l
Free from corrosive liquids or gases
l
Free from explosive liquids or gases
l
Free from powerful electromagnetic inter-
ference
Table 3-2: Environmental and operating conditions of the 2-Finger Adaptive Gripper
3.4. Mechanical Installation
3.4.1. Installing the Gripper on the robot
Single Gripper Installation
You must use a coupling to attach the gripper to the robot. Be sure to use the coupling related to your robot model. If there is no
coupling for your robot, you can modify a blank coupling. Some couplings may require an additional adapter plate. To create your
own coupling or adapter plate you can refer to the Couplings section. To see the details of the available couplings and adapter
plates, please refer to the Spare Parts, Kits and Accessories section.
19