AirPick - Instruction Manual
Info
All specifications are measured with coupling GRP-CPL-062.
Chart 6-2: Flow (L/min) vs Vacuum (%)
6.2.1. Payload and force
When a load is to be picked by a Vacuum Gripper, several factors have to be considered. One of them is the vacuum level
percentage selected. This value represents the pressure difference between the inside of the system and the ambient pressure.
This table is valid for a nominal atmospheric pressure of 101.3 kPa.
Vacuum level (%)
Pressure difference (kPa)
0
0
10
10.1
20
20.3
30
30.4
40
40.5
50
50.7
81