AirPick - Instruction Manual
6.2.3. Moment Limitation
The Vacuum Gripper has a maximum moment. The listed moment is independent to the force applied by the Gripper itself on it's
payload. For payload calculation, refer to the Mechanical specifications section.
Warning
The following limits must be respected at all time. Calculation of maximum moment should include the robot
acceleration and a safety factor.
Parameters
Maximum Value
Total moment
150 Nm
Table 6-5: Moment limitation of the Vacuum Gripper
6.3. Electrical specifications
SPECIFICATION
VALUE
Operating supply voltage
24 VDC ± 10%
Quiescent power (minimum
power consumption)
1.2 W
Peak current
150 mA for 100 ms when vacuum pump starts
Table 6-6: Vacuum Gripper electrical specifications