3.4.2. Installing the Hand-EGripper onto e-Series robots
The use of a coupling to attach the Hand-E Gripper to the robot is necessary. Please consult the Spare Parts, Kits and Accessories
section in the Hand-E Instruction Manual to consult the list of couplings available.
Here are the steps to mount the Hand-E on the robot (exploded view in the figure below). Note that all screws should be locked using
medium strength threadlocker.
1
Mount the coupling on the robot tool flange. Align using the dowel pin.
2
Secure by inserting the M6 screws and tooth lock washers.
3
Mount the Hand-E Gripper onto the coupling using M5 screws and align it with the dowel pin.
4
Secure the gripper to the coupling.
5
Cover the connector by installing the wrist connection protector using the M4 screws.
Fig. 3-3: Installing the Hand-E Gripper on the robot tool flange