3.4.3. Installing the FT Sensor and the Hand-Eonto CB-Series robots
Step 1: Installation of the Robotiq Force Torque Sensor
The installation of the FT Sensor is necessary on CB-Series robots for force and torque data acquisition.
Standard delivery for an FT Sensor kit:
FTS-300-KIT-001
Robotiq Force Torque Sensor FT 300 unit
1 m pigtail cable (CBL-COM-2068-01)
10 m Robotiq Device Cable (CBL-COM-2065-10-HF)
USB Signal Converter (ACC-ADT-USB-RS485)
Info
The FT 300 coupling is mandatory, you can customize yours from a blank provided by Robotiq.
Here are the steps to follow for the installation of the Sensor (see figure below). Note that all screws must be locked in place using
medium strength threadlocker, such as Loctite 248 or a similar product.
1. Align the indexing dowel pin between the coupling and the robot (usually press fitted to the robot).
2. Screw the coupling to the robot with the robot mounting screws (with lock washers if provided) and threadlocker.
3. Align the Sensor indexing dowel pins (prefixed to the Sensor) to the coupling.
4. Screw the Sensor to the coupling using the coupling mounting screws (with lock washers if provided) and threadlocker.
20