Register mapping for the Simplified Control Mode :
Caution
Byte
and not at 1 for the functionalities and status registers.
numeration starts on zero
REGISTER
ROBOT OUTPUT /
FUNCTIONALITIES
ROBOT INPUT / STATUS
Byte 0
ACTION REQUEST
GRIPPER STATUS
Byte 1
00
OBJECT DETECTION
Byte 2
00
FAULT STATUS
Byte 3
POSITION REQUEST
POS. REQUEST ECHO
Byte 4
SPEED
FINGER A POSITION
Byte 5
FORCE
FINGER A CURRENT
Byte 6
00
NOT USED IN SIMPLE MODE
Byte 7
00
FINGER B POSITION
Byte 8
00
FINGER B CURRENT
Byte 9
00
NOT USED IN SIMPLE MODE
Byte 10
00
FINGER C POSITION
Byte 11
00
FINGER C CURRENT
Byte 12
00
NOT USED IN SIMPLE MODE
Byte 13
00
SCISSOR POSITION
Byte 14
00
SCISSOR CURRENT
Byte 15
RESERVED
RESERVED