Robotiq 3-Finger Adaptive Robot Gripper
Instruction Manual
Robotiq inc. © 2008 - 2014
86
where
BITS
DESCRIPTION
34AB
Unique transaction identifier (chosen randomly)
0000
Protocol Identifier (Modbus)
0006
Length
02
SlaveID
10
Function Code 16 (Preset Multiple Registers)
03E8
Address of the first register
0003
Number of written registers
Step 8: Read Gripper status until the opening is completed
Request is:
D6 05 00 00 00 06 02 04 07 D0 00 08
where
BITS
DESCRIPTION
D605
Unique transaction identifier (chosen randomly)
0000
Protocol Identifier (Modbus)
0006
Length
02
SlaveID
04
Function Code 04 (Read Input Registers)
07D0
Address of the first requested register
0008
Number of registers requested (8)
Example of response if the opening
:
is not completed
D6 05 00 00 00 0D 02 04 10 39 C0 00 00 B8 0B 00 BD 0E 00
BA 0B 00 89 00 00