7.5 Gripper Palm Replacement
Maintenance interval
Tools you need
Parts you need
1 M cycles or when wear is visible
2.0mm precision flat head
screwdriver
Dry tissue or towel
Phillips screwdriver
Palm pad S-071 (from Robotiq).
six (6)
4-40 X 1/4 Flat Head
Machine Screws (Philips, zinc
coated).
Low strength thread-locker
(Loctite 220)
See
section to order Robotiq 3-Finger Adaptive Robot Gripper replacement parts.
Spare Parts, Kits and Accessories
Note
Always turn off robot and Gripper power supply before performing maintenance operations on
the Gripper.
Procedure
Remove the Gripper from the robot following schematics in section
.
Clean the Gripper following instructions in
Remove the Palm Pad as described in section
.
Clean the Palm, especially the space under the Palm Pad of any debris or residue.
Fix the new Palm Pad (custom or standard) as illustrated in section
. Use low strength
Loctite
on the screws.