Register: SPEED
Address: Byte 4
Bits
7
6
5
4
3
2
1
0
Symbol
rSP
This register is used to set the Gripper closing or opening speed in real time, however, setting a speed will not initiate a motion.
l
0x00 - Minimum speed
l
0xFF - Maximum speed
l
Register: FORCE
Address: Byte 5
Bits
7
6
5
4
3
2
1
0
Symbol
rFR
The force setting defines the final gripping force for the Gripper. The force will fix the maximum current sent to the motor . If the current
limit is exceeded, the fingers stop and trigger an object detection notification. Please refer to the Picking Features section for details on
force control.
l
0x00 - Minimum force
l
0xFF - Maximum force
Info
Register bytes 6 to 15 are reserved and should be set to 0.