Robotiq Hand-E Gripper - Instruction Manual
Step 3: Move the robot to the pick-up location
Step 4: Close the Gripper at full speed and full force
Request is: 09 10 03 E8 00 03 06 09 00 00 FF FF FF 42 29
Bits
Description
09
SlaveID
10
Function Code 16 (Preset Multiple Registers)
03E8
Address of the first register
0003
Number of registers written to
06
Number of data bytes to follow (3 registers x 2 bytes/register = 6 bytes)
0900
Value written to register 0x03E8 (ACTION REQUEST = 0x09 and GRIPPER OPTIONS = 0x00): rACT = 1 for "Activate
Gripper", rGTO = 1 for "Go to Requested Position"
00FF
Value written to register 0x03E9 (GRIPPER OPTIONS 2 = 0x00 and POSITION REQUEST = 0xFF): rPR = 255/255 for full
closing of the Gripper
FFFF
Value written to register 0x03EA (SPEED = 0xFF and FORCE = 0xFF): full speed and full force
4229
Cyclic Redundancy Check (CRC)
Response is: 09 10 03 E8 00 03 01 30
Bits
Description
09
SlaveID
10
Function Code 16 (Preset Multiple Registers)
03E8
Address of the first register
0003
Number of written registers
0130
Cyclic Redundancy Check (CRC)
52
Summary of Contents for HAND-E
Page 30: ...Robotiq Hand E Gripper Instruction Manual Fig 4 1 Hand E control logic overview 30 ...
Page 86: ...9 Troubleshooting Section to be populated soon Robotiq Hand E Gripper Instruction Manual 86 ...
Page 91: ...Robotiq Hand E Gripper Instruction Manual 12 3 Ingress Protection Certificate 91 ...