Palletizing Solution - Instruction Manual
3.3.1. AirPick Gripper Air Supply
Compressed air must be supplied to the Vacuum Gripper according to the technical specifications. For maintenance and other
purposes, it is recommended to install a lockout valve before connecting to the product. The air supply tubing must be connected and
disconnected to, or from, the inlet port, only when the line is depressurized. When the line is pressurized, the safety clip must be at all
times installed on the inlet port.
To protect against whipping hazard, the air supply tubing must be securely attached to the robot arm. An air fuse should also be
installed.
3.3.2. Depressurizing the Supply Line
In order to safely depressurize the supply line, the air supply must first be shut off. Then, if no lockout valve is present to depressurize
the line, the AirPick Gripper can be activated until the pressure is fully released.
3.4. Mounting and Installation
3.4.1. Visual Inspection
The Robotiq Palletizing Solution is shipped on a pallet. A wood crate is protecting the hardware from external elements. Before
removing the crate, make an inspection of it to make sure there is no damage or defect. If it's the case, you must contact Robotiq
support team.
Caution
Before removing the crate, make sure you have inspected it.
3.4.2. Unboxing
Tip
A minimum of two people is recommended for the following steps.
23
Summary of Contents for PALLETIZING SOLUTION
Page 12: ...Palletizing Solution Instruction Manual 12...
Page 72: ...6 1 2 AirPick Vacuum Gripper Fig 6 1 AirPick general dimensions 72...
Page 73: ...Palletizing Solution Instruction Manual 6 1 3 Extra Reach Bracket 73...
Page 74: ...6 1 4 Bracket for two 2 Suction Cups Fig 6 2 Two air nodes bracket s dimensions 74...
Page 80: ...80...
Page 95: ...1 2 2 Safety Connections Fig 12 2 Universal Robots Controller Safety Connections Schema 95...