RBTNK-DOC-
161020
Hardware Manual.
RB-1 Modular Mobile Manipulator
6 Maintenance
The following table shows some elements that need maintenance and
the periodicity of this maintenance.
Often
Every 6 month
Observations
Screws
Check they are
not loosen.
Tires
Visual control of the
wear rate.
Replace when
needed
Outer wires
Visual control of the
wear rate.
If wear appears,
protect them with
Shrink tube,
Vulcan tape or
similar.
Bearings
Control state.
If any damage
appears, it is
recommended its
replacement by a
new one.
Battery
Control
Batteries
Voltage, don’t
let the batteries
get fully
discharged
Check battery
autonomy
Recharge ASAP if
fully discharged
PC
Interior Cleaning.
Visual control of the
correct work of the
fan (if installed).
Table 4 – Maintenance summary