ROBOVENT •
DFS SERIES OWNER’S MANUAL
34
FRAM SIZE
MOTOR HP
GREASE AMOUNT IN GRAMS
3600 RPM
1800 RPM
254 / 6T
20 HP
13 grams
15700 hours
20000 hours
284 / 6T
30 HP
18 grams
11500 hours
20000 hours
324 / 6T
40 HP
21 grams
9800 hours
20000 hours
364 / 5T
60 HP
27 grams
3600 hours
9700 hours
404 / 5T
100 HP
27 grams
3600 hours
9700 hours
444 / 5TS
125 HP
27 grams
3600 hours
9700 hours
RELUBRICATION
INTERVALS IN HOURS
324 / 5T
40 HP
21 grams
9800 hours
20000 hours
364 / 5T
60 HP
27 grams
4800 hours
9700 hours
404 / 5T
100 HP
34 grams
3000 hours
6000 hours
444 / 5T
125 HP
45 grams
2300 hours
4700 hours
Relubrication Time Interval & Amount of Grease
SECTION 1000
Motor Greasing Guide