575 Volt ProCube Owner's Manual & Operating Instructions
E1-20171020
©2017 ROBOVENT PRODUCT GROUP, INC.
12
Operating Instructions
Refer to diagram below for callouts of the control interface located on top
of the filter access. Below are descriptions of the simple control modes.
More than six starts of the motor in one hour can be harmful. Refer to
the “Purpose & Limitations” section for a detailed description.
Manual Mode Operation
Once airflow has been set up according to the “Testing & Commissioning”
section, manual mode is simple to operate – just on when you need it, off
when you don’t. The blower is rated for continuous duty, so it can run for a
complete shift if needed.
AutoSaver Mode Operation
The automatic mode is controlled by optional sensors on the weld unit‘s
power cord. The optional cables connect to the rear of the machine.
Simply turn the mode switch to the far right ‘auto’ position and begin
welding. The sensor will detect an increase in power drawn by the welder
and signal the ProCube unit to start. Adjustment of the sensors’ threshold
screw may be required.
Pulse Cleaning
The ProCube machine is equipped with electronic pulse cleaning. Two
modes are automatically activated, ‘online’ and ‘offline’. Online cleaning
pulses the unit after it has been running for 30 minutes continuously.
Once the unit has been shut off after a 30-minute or longer work period,
an offline pulsing cycle will be initiated. An additional pulsing cycle can be
manual enacted after offline pulsing has run, by pressing the pulse button.
One-Gun / Two-Gun Switch
Hour Meter
Pulse Button
Mode Switch
OFF / ON / AUTO
Filter Differential Pressure
Filter Differential Pressure
Yellow Warning Light
Alarm
Green Running Light
Right Speed Dial
2-Gun Setting
Left Speed Dial
1-Gun Setting