575 Volt ProCube Owner's Manual & Operating Instructions
E1-20171020
©2017 ROBOVENT PRODUCT GROUP, INC.
5
Introduction
PREREQUISITES FOR USE
All users and maintenance personnel must read this manual before install-
ing, operating, or servicing the RoboVent ProCube. Maintenance personnel
must thoroughly understand the troubleshooting and servicing sections of
this manual.
The machine requires compressed air and electrical connections:
• Compressed air must be regulated to 5.86 bar (85 PSI) and must be
clean and dry according to ISO 8573-1 Class 7. It is recommended to
connect to the machine with a quick-disconnect fitting and flex-
ible hose for portability and easy disconnection when performing
maintenance.
• Electrical supply must be 400 Volts at 50 Hertz. The supply circuit
shall be protected and capable of providing 5.1 Full Load Amps.
• Power cord and air connection are at rear of machine.
The machine will require adjustment of airflow to ensure effective capture;
refer to the operating instructions. It is recommended to check airflow at
the beginning of each shift to ensure fumes are being captured and set-
tings are maintained.
When operating with both inlets, a two-inch ball valve may be required
for balancing airflow. Refer to the "Testing & Commissioning" section.
The machine is limited by the amount of vacuum it can safely create. Too
much resistance by such conditions as unsuitable hose, excessive hose
length or constricted intake can overload the blower and prevent it from
successfully capturing fumes. Changes can be made to setup if machine
does not perform as expected. Review "Testing & Commissioning"
section If you need assistance with adjustment or setup, please contact
RoboVent Customer Service & Tech Support at 888-ROBOVENT.