6
Remote control unit mounting location
The remote control unit should be mounted on the wall which is on the side where the toilet's
remote control light receptor is located (left side).
If it is necessary to mount the remote control unit on the opposite wall side, make sure the remote control
signals can be received from that position.
In the case also that the remote control unit's light receptor side wall has a wash stand installed and there
is quite some distance to the toilet, the light receptor may not pick up the remote control unit’s signals.
In such a case, install a screen that will reflect the signals within 1300 mm of the center of the toilet.
* Please provide a suitable screen at the site where the toilet is being installed.
The screen’s dimensions should be 1100 mm or greater in height and the W should assure the distance
from the remote control unit's light receptor to the remote control unit’s installation position. (However,
this will differ somewhat depending on the wall's finish, color and other conditions. Be aware that.)
Water supply hose
Connect the water supply pipe securely to the toilet.
* Failure to do so could result in water leakage.
Water supply location
Install the water shutoff valve, then perform the construction required to install the toilet body. The
positions where the water supply pipe and drain pipe should be set are as shown below.
If the remote control unit is
mounted on the left side wall
If the remote control unit is
mounted on the right side wall
Light Receptor
Screen
Light Receptor
Remote
Control
Unit
Remote
Control
Unit
1300 mm or less
W
100
100
280
210
280
330
300 or longer
If water is supplied through the floor
Drain Pipe
If water is supplied from
the wall