7
the controller for 60 minutes. This function stop all func-
tions without need of disconnecting the power supply. To
switch on this function, press this button
FILTER
5 seconds.
After switching this function on, the “Sby” sign will appe-
ar together with the time left to the end of this function.
There are three methods to stop this function automati-
caly:
●
Wait 60 minutes until this function stops.
●
Press this button
FILTER
for longer than 5 seconds when
the function works.
●
Disconnect the controller from the power supply.
The “Stand-By” function blocks the
fi
ltration function. If 40
minutes after going out from “Stand-By” mode SPA still
will be in
fi
ltration period,
fi
ltration mode will start again.
2.11. Control panel keyboard locking
Partial keyboard locking:
●
Press and hold this button
ECONO
. During this operation,
the key-shaped icon blinks.
●
The LocP sign will appear on the display after pressing
this button on the control panel for 3 seconds. Once this
sign has appeared, the function becomes active and the
key icon is on permanently. The main and optional con-
trol panel are locked.
●
Release the button.
●
Following keys are blocked now: jets, light air/aux and
all the keys in optional panel.
To unlock the panel, press and hold this button
ECONO
for
not less than 5 seconds.
The LocP sign will appear on the display if any button is
pressed after locking the keyboard. The partial keyboard
locking function is not remembered after a power cut-
off.
Total keyboard locking:
●
Press and hold this button
ECONO
. The key-shaped icon
blinks during this operation.
●
The “LocP” sign will appear on the display after pres-
sing this button on the control panel for 3 seconds. Once
this sign has appeared, the function becomes active and
the key icon is on permanently. The main and optional
control panel are locked.
●
Keep this button pressed.
●
After 5 seconds the LocF sign appears, and since that
moment the function is active.
●
Release the button.
All the buttons in both panels are locked.
To unlock the panel, press and hold this button
ECONO
for
not less than 5 seconds.
The LocF sign will appear on the display if any of the loc-
ked buttons is pressed after locking the keyboard. The
total keyboard locking function is not remembered after
a power cut-off.
2.12. Frost protection (ANTIFROST System / Smart
Winter Mode)
Most important task of SPA electronic system is holding
temperature of water within the range between 15 to 40
0
C. However electronic system has additional feature -
winter operation mode (Antifrost/Smart Winter mode)
which protects piping against frozing.
PCB integrated temperature sensor continously controls
air temperature which surronds electronic system. If air
temperature decrease below 15
0
C electronic system
starts winter mode. In this mode system switches on eve-
ry pump for 1 minute (one by one). Frequency of pumps
operations is connected with surrounding temperature
and is presented in the table below. Water heater works
independently of air temperature sensor, it depends only
of water temperature sensor.
Temperature
0
C
Operating frequency (min)
12 < t
≤
15
120
9 < t
≤
12
60
6 < t
≤
9
30
t
≤
6
15
• Operation mode ANTIFROST system is marked by ICE
symbol on the LCD screen.
• Stand by mode doesn’t affect on ANTIFROST system
operations.
• All these functions are not available until ICE symbol
disappered. It is possible to take a bath.
• If electronic system detects temperature below 150 C
degrees of the surrounding air then ANTIFROST sys-
tems starts after 15 minutes from last pump switch off.
• If during
fi
ltration mode ANTIFROST system starts,
fi
l-
tration mode will be switch off.
REMEMBER TO KEEP SPA CONNECTED TO ELEC-
TRIC SUPPLY FOR PERMAMENT ACTIVATION OF
ANTIFROST SYSTEM.
Hydromassage & airmassage
active
Hydromassage & airmassage
active
3. OZONE
The ozone generator works during the
fi
lter cycles for
puri
fi
cation purposes, keeping the water clear and hy-
gienic.
The ozone generator produces active O
3
molecules from
the air. These molecules are sucked in from the ozone
generator to the water injector. The O
3
mixed with the
water kill the bacteria in contact with the water.
Summary of Contents for SPA BROADWAY ROUND
Page 1: ...1 User s Handbook SPA BROADWAY ROUND...
Page 11: ...11...