49
Troubleshooting Charts
Power Problems
Fault
Symptom
Possible Cause
Jukebox fails to operate at all when it is
plugged in and the blue power button
has been pressed
NOTE: Be sure all devices are
connected per primary Power Diagram
LED's on Amplifier all dark
LED's on remote interface dark
Core fan not running
•
Main Power switch not on
•
Plug not in wall outlet or
Distribution Box
•
Outlet "Dead"
•
"Tripped" Circuit Breaker on
Power Box
•
Core not turned ON
•
Defective Core
No cabinet lights or sound
Application running on screen
•
Control cable not plugged into
Power Box or remote volume
interface
•
Lights not plugged into “lighting”
connector on amplifier
•
Junction box on door not plugged
in
Touchmonitor Problems
Fault
Symptom
Possible Cause
Monitor "Dead"
Cabinet lights on
Nothing on the screen
Monitor power cable not plugged into
core.
Monitor not plugged into CORE Video
Output. (Dark blue connector)
Defective Monitor or Core
Touch Screen does
not respond.
Touch Screen not Calibrated
Run calibration routine by following the
procedure on page 11.
Calibration Routine Fails
Serial Cable not plugged into Core or
Monitor ( Teal connector)
Liquid on the screen
Defective Touch Monitor