SECTION 4—REPLACEMENT PARTS
Detect-A-Finger™ Drop Probe Device - Riveter
SECTION 5—TROUBLESHOOTING
Detect-A-Finger Drop Probe Device - Riveter
TERMINAL
From
To
a
b
b
a
a
c
c
a
d
b
b
d
d
c
c
d
RESISTANCE MEASUREMENTS — Power off with components not connected.
(a)
(b)
(c)
(d)
RESISTANCE
OHMS
700
•
700
•
•
700
•
700
Part No.
Description
Qty.
RFC-057
Relay, 120 volt coil
1
RYK-001
Rectifier, half wave
1
RYK-007
Rectifier, full wave bridge
1
RTY-014
Fuse, 3 amp
1
CTS-013
Indicator light, red (neon)
1
CMC-020
Limit switch
1
FTL-022
P.C. Board
1
Part No.
Description
Qty.
FCT-030
Sensing probe
2
FCT-029
Clamp (nylon)
1
CMF-109
Rotary solenoid (right)
1
CMF-110
Rotary solenoid (left)
1
FKC-101
Spring 1
FCT-043
Drop rod assembly repair kit
1
Check mechanical moving parts for excessive wear on a regular basis. We recommend that the following components be stocked as replacement parts.
(-DC)
AC
AC
(+DC)
Bridge Rectifier, Terminal Identification:
SYMPTOM
TEST POINTS
READING
PROBLEM
“Power On” Indicator
Will Not Light
“Power On” Indicator is
Lit, Rotary Solenoid
Will Not Energize
“Power On”
Indicator is Lit,
Rotary Solenoid
Energizes, Machine
Will Not Cycle
Terminal 2-3
Terminal 6-3
Terminal 7-3 with
Foot Switch depressed
Across relay coil with
Foot Switch depressed
Terminal 8-3 with Foot Switch
depressed
Terminal 8-4 with Foot Switch
depressed
Terminal 5-4 with Foot Switch
depressed
0
60 VAC
230 VAC
115 VAC
0
115 VAC
0
115 VAC
0
115 VAC
0
115 VAC
0
115 VAC
0
115 VAC
No primary power.
Transformer wired for 460 VAC, 240 applied.
Transformer wired for 230 VAC, 480 applied.
Proper voltage applied, continue.
Fuse blown, replace.
Defective lamp, replace.
Foot Switch defective or improperly connected,
locate problem and correct.
Proper voltage - bridge rectifier or rotary solenoid
defective. See resistance measurement section.
Limit Switch not being actuated or Limit Switch defective. Perform
adjustment procedure or replace Limit Switch.
Proper voltage — relay coil open.
Jumper 7-8 missing.
Proper voltage, continue.
Jumper 4-3 missing.
Proper voltage, continue.
Relay contact defective — replace relay.
Proper voltage — machine operating device or wiring defective —
check continuity with an ohmmeter.
VOLTAGE MEASUREMENTS (120 VAC Type Machine Operating Device)
Readings may vary slightly from meter to meter. However, the trend
established between infinity (
•
) and the lower readings must remain
consistent throughout the test. Any unusual reading means the bridge
rectifier is defective and must be replaced.
Rotary Solenoid
- Resistance 109 Ohms.
Clutch Actuating Equipment
- AC Type push or pull solenoids have
DC resistances typically less than 10 Ohms. AC solenoid air valves of
the type usually supplied have approximately 100 Ohms DC resistance.