background image

3

NOTE:

Vb is the gross volume, which is the TOTAL internal volume, before any speaker and/or port displacement.
All external dimensions were based on the use of 3/4" (1.90cm) materials.

NOTE:

When using enclosures other than recommended, call Technical Support for correct application.

NOTE:

Vb is the gross volume, which is the TOTAL internal volume, before any speaker and/or port displacement.
All external dimensions were based on the use of 3/4" (1.90cm) materials.

NOTE:

When using enclosures other than recommended, call Technical Support for correct application.

S

EALED

E

NCLOSURES

V

ENTED

E

NCLOSURES

Specifications subject to change without notice

Optimum Sealed Enclosure Recommendation

Recommended Sealed Enclosure Volume Range

SEALED ENCLOSURES

10"

12"

R2D2-10 / R2D4-10

R2D2-12 / R2D4-12

Vb- Internal Area cu. ft.

0.59

1.02

(Liter)

(16.7)

(28.9)

F3- -3dB Point (Hz)

57.5

51.4

Qtc- Enclosure Damping

0.75

0.94

H - Height-inch

15.75

17.5

(cm)

(40.01)

(44.45)

W - Width-inch

17.5

18.5

(cm)

(44.45)

(46.99)

D - Depth-inch

6.25

8.25

(cm)

(15.88)

(20.96)

SEALED ENCLOSURES

10"

12"

R2D2-10 / R2D4-10

R2D2-12 / R2D4-12

Vb- Volume Range cu. ft.

0.50 to 0.75

0.75 to 1.25

(Liter)

(14.16 to 21.24)

(21.24 to 35.40)

Specifications subject to change without notice

Number of ports noted in ( )

Optimum Vented (Ported) Enclosure Sizes

VENTED ENCLOSURES

10"

12"

R2D2-10 / R2D4-10

R2D2-12 / R2D4-12

Vb- Internal Area cu. ft.

1.40

1.79

(Liter)

(39.6)

(50.7)

Fb- Tuning Frequency (Hz)

43.0

45.0

F3- -3dB Point (Hz)

37.1

39.4

H - Height-inch

14.0

16.5

(cm)

(35.56)

(41.91)

W - Width-inch

17.0

20.5

(cm)

(43.18)

(52.07)

D - Depth-inch

15.25

13.0

(cm)

(38.74)

(33.02)

P - Port Diameter and

Length-inch

(1) 4 x 13

(1) 4 x 9.3

(cm)

(1) (10.16 x 33.30)

(1) (10.16 x 23.70)

NOTE:

The port shown can be placed on any face of the enclosure as long as the port ends are not obstructed.

NOTE:

When using vented enclosures, for maximum reliability and power handling ensure that a subsonic or "infrasonic" filter is used so that
only usable low frequency signal is sent to the subwoofer.

Summary of Contents for Prime R2D2-10

Page 1: ...Installation Operation R2 DVC DUAL VOICE COIL SUBWOOFERS Serial Number Date of Purchase 10 12 Dual 2 Ohm R2D2 10 R2D2 12 Dual 4 Ohm R2D4 10 R2D4 12 ...

Page 2: ...rk properly the walls of the enclosure must be rigid and not flex when subjected to the high pressures generated by the speaker s operation For optimum performance we recommend using 3 4 MDF Medium Density Fiberboard and internal bracing The enclosure should be glued together and secured with nails or screws CALCULATING VOLUME Calculating volume is merely a matter of measuring the dimensions in in...

Page 3: ...sure Damping 0 75 0 94 H Height inch 15 75 17 5 cm 40 01 44 45 W Width inch 17 5 18 5 cm 44 45 46 99 D Depth inch 6 25 8 25 cm 15 88 20 96 SEALED ENCLOSURES 10 12 R2D2 10 R2D4 10 R2D2 12 R2D4 12 Vb Volume Range cu ft 0 50 to 0 75 0 75 to 1 25 Liter 14 16 to 21 24 21 24 to 35 40 Specifications subject to change without notice Number of ports noted in OptimumVented Ported Enclosure Sizes VENTED ENCL...

Page 4: ... 10 R2D2 12 R2D4 12 A Overall Diameter inch 10 84 12 97 mm 275 329 B Screw Hole Diameter inch 10 16 12 28 mm 258 312 C Mounting Depth inch 4 33 5 10 mm 110 129 D Mounting Diameter inch 9 13 11 22 mm 232 285 E Speaker Displacement cu ft 0 101 0 150 Liter 2 85 4 25 PHYSICAL DIMENSIONS ...

Page 5: ... a range of options for impedance loads Series Parallel or Series Parallel wiring configurations are different techniques for wiring speakers that provide different loads Series configuration is a string method where speakers are wired end to end Parallel configuration uses two or more speakers wired across common terminals Series Parallel configuration combines both techniques Choose the wiring d...

Page 6: ...du caisson Les différents côtés devront être collés colle à bois et vissés ou éventuellement cloués Il est recommandé de mettre un joint de silicone dans les arêtes internes du caisson afin d éviter les fuites d air Calcu duVolume On calcule le volume en mesurant la dimension de chaque côté et en utilisant la formule suivante Si les due côtés qui se font face n ont pas la même longueur additionnez...

Page 7: ...ncoladas y aseguradas con tornillos o grapas Internamente los bordes deben ser sellados con silicona para prevenir las fugas de aire La cola para madera es la mejor opción Cálculo deVolúmenes Para calcular el volumen sólo se han de medir las dimensiones en centímetros y aplicar la fórmula Si dos caras opuestas son de diferente tamaño súmelas y divida el total por dos para obtener el promedio Usand...

Page 8: ...nd interneAussteifungen Das Gehäuse wird verleimt und mit Nägeln oder Schrauben befestigt Da Faserplatte luftdurchlässig ist wird geraten das Gehäuse von außen mit Polyurethan zu behandeln Berechnung des Volumens Zur Berechnung desVolumens einfach die Maße feststellen und folgende Formel anwenden Sind zwei gegenüber liegende Seiten ungleich lang die Durchschnittslänge der beiden Seiten berechnen D...

Page 9: ...anyone other than Rockford or an Authorized Rockford Fosgate Service Center 4 Any product which has had the serial number defaced altered or removed 5 Subsequent damage to other components 6 Any product purchased outside the U S 7 Any product not purchased from an Authorized Rockford Fosgate Dealer Limit on Implied Warranties Any implied warranties including warranties of fitness for use and merch...

Reviews: