background image

6

Code

Description

Action

E1

Battery Voltage is low.

as required. 

E2

Fan failure / Frequent start-stop.

Contact point of sale to arrange further action. 

Check battery voltage and adjust Low Voltage Cut-Off

E3

Compressor startup problems.

Check air vents are clear. 

 

Move fridge to cooler location (ambient temperature 

may be too high). 

E4

Compressor’s running speed fails 

to reach the requirements.

E5

The model is overloading.

E6

NTC failure(open circuit or short 

circuit)

TROUBLESHOOTING:

LOW

MED

HIGH

9.6

10.4

11.1

10.9

11.7

12.4

21.3

22.8

24.3

22.7

24.2

25.7

● Battery protection Level

Battery protection

(SWITCH POSITION)

Cut-out 12V Cut-in 12V

Cut-out 24V Cut-in 24V

Power on, short press the "        " button to switch the "Max" and "eco" modes (the default mode max).

Cooling Mode Control:

● In standby mode, press and hold the key "        " and "        " for 3 seconds to display the current 
corresponding battery protection status and flash. At this time, short press "        " or  "        " to switch 

the protection gears (the default is high gear).

Battery Protection:

In standby mode, press and hold the "        " key for 3 seconds to display the current corresponding 
display mode, and short press the "        " key for "C" and "F" to switch. The default value is "C" and it 

will return to standby mode after 3 seconds of no operation.

Switch between Centigrade "C" and "Fahrenheit" F "

Reviews: