7
Fig.1 Fig.2 a Fig.2 b
4.1.4. Put down the guard and press
to perform a measuring spin.
4.1.5. In a few seconds the wheel is brought to operating speed and begin measuring unbalance, the unbalance values
remain on instruments 1 and 3 when the wheel stopped. Press
may check the real unbalance value under threshold.
4.1.6. Anticlockwise moving wheel slowly, until the right LED lit up full, clip weight on 12 o’clock position (Fig.3)
Fig. 3
4.1.7
.
Anticlockwise moving wheel slowly, until the left LED lit up full, clip weight on 12 o’clock position (Fig.4)
Fig. 4
4.1.8
.
After finishing clipping the counterweights, put down the guard and press
,
to perform balancing spin
again, if comes out 00 00
,
means balancing succeed. (Fig.5)
Fig. 5
4.2
.
ALU-1 mode (ALU-1, ALU2, ALU 3
,
ALU 4
,
ALU5, same operation, only the position to add
weights different)
4.2.1. Set “a” “d” “b” values
4.2.2. Press
until ALU1 indicator lit up