8
4.2.3. Put down the guard and press
to perform a measuring spin.
4.2.4. In a few seconds the wheel is brought to operating speed and begin measuring unbalance, the unbalance values
remain on instruments 1 and 3 when the wheel stopped. Press
may check the real unbalance value under threshold.
4.2.5. Anticlockwise moving wheel slowly, the displays with right LED’s lit up full indicate the correct angular position
where to mount the counterweights, 12 o’clock position outside, as Fig.6, add the counterweight.
Fig. 6
4.2.6. Anticlockwise moving wheel slowly, the displays with left LED’s lit up full indicate the correct angular position
where to mount the counterweights, 12 o’clock position inside, as Fig.7, add the counterweight.
Fig. 7
4.2.7. After finishing mounting the counterweights, put down the guard and press
,
to perform balancing spin
again, if comes out 00 00
,
means balancing succeed. (Fig.8)
Fig. 8
4.3
.
ALU
-
S mode
This mode is used for special rim, if ALU1/ALU2 can not be used, you should choose ALUS mode.
Input aI, aE, d value
⚫
Set “aI”: pull gauge out let the gauge head touch the position of FI for 4 seconds, may press
and
and
to change