Internal Floating Piston (IFP) Installation
600 Hour S e r v i c e
I n t e r n a l F l o a t i n g P i s t o n ( I F P ) I n s t a l l a t i o n
Fully coat the inside and outside surfaces of the IFP tube with Reverb
fluid.
Install the IFP tube with the cross holes facing up, into the upper post.
Use your finger to rotate the IFP tube in a circular and side to side
motion until the IFP tube seats itself onto the seal inside the bottom of
the upper post.
Push down firmly on the IFP tube until it snaps securely into the upper
post. When the IFP tube snaps into place, a click will be heard. Ensure
the IFP tube is secured and centered.
NOTICE
Do not scratch the inside of the upper post with the IFP tube.
Scratches can cause leaks.
The IFP tube should be below the top of the upper post when it is
installed correctly.
Secure shop towels around the upper post below the open end of the
tube and above the top cap to absorb displaced hydraulic fluid.
NOTICE
To avoid damage to the electronics, do not allow fluid to overflow
onto the electronics compartment.
Pour Reverb hydraulic fluid into the IFP tube until the fluid overflows
into the upper post and is level with the top of the upper post.
Use your finger to remove any bubbles from the surface of the fluid if
bubbles are visible.
1
2