Rockwell Automation Publication 1441-UM002A-EN-P - May 2011
17
Bump Test Extension Module
Chapter
2
Bump Test Parameter Descriptions on page 17
for complete
descriptions of the parameters.
5.
Configure the Bump Test setup parameters.
Table 2 - Bump Test Parameter Descriptions
Parameter
Description
Value
Num. Channels
Number of Channels you are using
in the Bump Test.
1 (X)
2 (X and Y)
3 (X, Y, and Z)
4 (X, Y, Z, R)
Sensor Type
Specifies the type of sensor used
(typically Accel G). Note that the
specified sensor type determines
available options and engineering
units for subsequent setup fields.
Accel (G) (default)
Accel m/s
2
Vel IPS
Vel mm/s
Disp um
Disp mil
Volts AC
Volts DC
Sensor Sensitivity
Enter transducer sensitivity in
millivolts (mV) per Engineering
Unit (EU) (typically 100 mV/g).
mV/EU
Range (EU) (Full Scale)
Define the spectrum’s maximum
full-scale amplitude value.
1 (default), 2, 5, 10, 20, 50, 100,
200, 500, 1000
Typically 20 G for Accel
X-axis units
Specify frequency units for graphic
displays.
Hz (default)
CPM
Filter
Displays high-pass filter settings.
2 Hz (default)
Off, 0.36 Hz, 1.1 Hz, 2Hx, 10 Hz,
70 Hz
Freq Range (Fmax)
The FFT upper full-scale
frequency, up to 40,000 Hz
(2,400,000 CPM).
1000 Hz (default)