7-10
LiquiFlo AC Power Modules, Hardware Reference Version 6.4
7.3
Wiring the Signal and Control I/O
Wire the drive’s signal and control I/O to the Regulator board terminal strip as shown
in table 7.8.
Table 7.8 – Wiring Signal and Control I/O to the Regulator Board Terminal Strip
Terminal
Number
Description
Parameters/Wiring Connections
Wiring RS-232 Signals
1
2
3
RS-232 Transmit
RS-232 Receive
RS-232 Signal/Regulator
Common
Note that RS-232 communication between the LiquiFlo
drive and a personal computer requires the use of the
Control and Configuration (CS3000) software. Refer to
instruction manual D2-3348 for more information.
These terminals should only be used when the RS-232 port
(J8) or an Operator Interface Module (OIM) are not being
used, as all three devices use the same transmit/receive
lines.
Wiring Encoder Inputs
4-9
Encoder Wiring
See section 7.2.
Summary of Contents for 41LR4060
Page 6: ...IV LiquiFlo AC Power Modules Hardware Reference Version 6 4 ...
Page 8: ...VI LiquiFlo 2 0 AC Drive User Manual ...
Page 10: ...VIII LiquiFlo 2 0 AC Drive User Manual ...
Page 12: ...1 2 LiquiFlo AC Power Modules Hardware Reference Version 6 4 ...
Page 30: ...2 18 LiquiFlo AC Power Modules Hardware Reference Version 6 4 ...
Page 40: ...3 10 LiquiFlo AC Power Modules Hardware Reference Version 6 4 ...
Page 50: ...4 10 LiquiFlo AC Power Modules Hardware Reference Version 6 4 ...
Page 78: ...7 22 LiquiFlo AC Power Modules Hardware Reference Version 6 4 ...
Page 90: ...9 10 LiquiFlo AC Power Modules Hardware Reference Version 6 4 ...
Page 96: ...B 2 LiquiFlo AC Power Modules Hardware Reference Version 6 4 ...
Page 98: ...C 2 LiquiFlo 2 0 AC Drive User Manual ...
Page 100: ...D 2 LiquiFlo 2 0 AC Drive User Manual ...
Page 102: ...E 2 LiquiFlo 1 5 AC Power Modules Hardware Reference Version 1 2 ...
Page 107: ......