PART NUMBER 40063-296-01
DIR 40063-296 (Version 03 )
Copyright © 2022 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.
Publication
800T-IN015C
-EN-P - March 2022
| Supersedes Publication 800T-IN015B-EN-P - August 2011
Product certificates are located in the Rockwell Automation Literature Library: rok.auto/certifications.
Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec.
EEE Yönetmeliğine Uygundur
.
For Technical Support, visit rok.auto/support.
ASIA PACIFIC:
Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2501846
expanding
human possibility
TM
EUROPE/MIDDLE EAST/AFRICA:
Rockwell Automation NV, Pegasus Park, De Kleetlan 12a, 1831 Diegem, Belgium, Tel: (32) 2663 0600, Fax: (32) 2663 0640
AMERICAS:
Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: 414.382.2000, Fax: (1) 414.382.4444
Knob Std. or Knob Lever
Lens Mounting
Octagonal Mounting
Ring
Panel
Grounding Screw
Transformer
Full Voltage
Mounting
Contact Block
Mounting Side
(White Actuator)
Thrust Washer
(Tang Engages Panel)
Trim Washer or
Legend Plate
Legend Plate and Thrust
or
Trim Washer and Thrust
Gaskets
PREFERED
METHOD
(4.4 mm)
11/64 in.
(17.1 mm)
43/64 in.
(46.8 mm)
1–27/32 in.
(57.2 mm)
2–1/4 in.
ø
(ø30.6 mm)
1–13/64 in.
ø1/4 in. DRILL
(ø6.4 mm)
ALTERNATE
METHOD
Minimum
Spacing
Figure 2. Hole Recommendation
Table 1
Gaskets required for various panel thicknesses.
Units are shipped with three 1/16 in. (1.6 mm) gaskets
16 gauge 1/16 in. (1.6 mm)
12 gauge 7/64 in. (2.8 mm)
10 gauge 9/64 in. (3.6 mm)
3/16 in. (4.8 mm)
3 gaskets
2 gaskets
2 gaskets
1 gasket
Panels thicker than 3/16 in. (4.8 mm) must be counterbored
to 3/16 in. (4.8 mm) thickness.
1. Remove lens mounting ring and knob or knob lever assembly.
2. Remove lamp by inserting the lens removal tool onto the lamp,
push down and rotate counter clockwise. Pull out the lamp.
3. Install a new lamp of the correct number. Refer to nameplate for
lamp number . Push lamp into socket using the lamp tool.
(Cat. No.: 800F-ALR1)
Rotate clockwise and pull lamp tool out once the lamp is retained.
4. Reinstall the lens assembly by placing the assembly over the shaft.
NOTE:
The shaft has a projection which should line up to the knob
indicator. Thread the lens mounting ring onto the bushing
once the knob is seated on the shaft.
An operator may be used with 1 or 2 of the contact blocks listed in Table 2, except as noted. Multiple contact blocks
must be mounted in tandem and may be in various combinations, two blocks maximum.
Relamping Instructions
Contact Block Mounting
Table 2
Number of Contacts
Standard Block
Pen
TUFF
TM
Low Voltage Block
Logic Reed
Block
Explosion-Protected
Contact Block
Stackable Sealed
Switch Block
1 N.O. – 1 N.C.
800T–XA
800T-XAV
800T–XAR
800TC-XAF
800T-XAY
1 N.O.
800T–XD1, 800T– XD5
800T-XD1V
800T–XD1R
800T-XD1Y
1 N.C.
800T–XD2, 800T–XD6
800T-XD2V
800T–XD2R
800T-XD2Y
1 N.O. (Early Make)
800T–XD3
800T–XA2R
1 N.C. (Late Break)
800T–XD4
800T–XA4R
1 N.C. (Late Break) – 1 N.O.
800T–XA1
1 N.C. (Late Break) – 1 N.C.
800T–XA7
2 N.O.
800T–XA2
2 N.C.
800T–XA4
1
1
N.O. = Normally Open, N.C. = Normally Closed
Mini contact blocks 800T-XD5 and XD6 may not be mounted directly behind the operator. Stack only on top of another contact block.
3
May be used in Class 1 Division 2 hazardous location applications in an enclosure suitable for the environment, which need not be
a hazardous location enclosure. (Refer to National Electric Code)
2
3
3
2
2
Figure 1.