Publication 900-UM007D-EN-E - January 2011
Configuration & Basic Operation
3-63
EXAMPLE
When the PV/SP Display Screen Parameter Is Set to 2
Figure 3.134
MV Display for Heating and
Cooling Control
Select either the manipulated variable (heating) or manipulated variable
(cooling) as the MV to be displayed for PV/SP/MV during heating and
cooling control. The MV Display Selection parameter is displayed only when:
1.
heating/cooling control is being performed and PV/SP/MV is selected
in the PV/SP Display Screen parameter
or
2.
a Monitor/Setting Item Display parameter.
EXAMPLE
PV/SP/MV and PV/SP/Multi-SP on the Process Value/Set Point Display
This procedure displays PV/SP/MV and PV/SP/Multi-SP on the Process
Value/Set Point display. The PV/SP Display Screen Selection parameter is set
to 2.
1.
Press the
O
Key for at least three seconds to move from the Operation
function group to the Initial Setting function group.
Figure 3.135
25
100
50.0
25
100
sp0
Press the
M
key
PV/SP/MV
PV/SP/Multi-SP
Operation Function Group
PV/SP (Display 1)
C
C
PV/SP (Display 2)
Table 3.R
Parameter Name
Set Value Symbol Display Contents
MV Display
Selection
O
o
Manipulated variable (heating)
C-O
c-o
Manipulated variable (cooling)
C
25
100
PV/SP
Input Type
in-t
5
Summary of Contents for Allen-Bradley 900-TC16
Page 1: ...USER MANUAL Bulletin 900 TC8 900 TC16 900 TC32 Series B Temperature Controllers...
Page 2: ...2...
Page 72: ...Publication 900 UM007D EN E January 2011 3 2 Configuration Basic Operation Figure 3 3 900 TC32...
Page 136: ...Publication 900 UM007D EN E January 2011 3 66 Configuration Basic Operation Notes...
Page 340: ...Publication 900 UM007D EN E January 2011 5 112 Parameter Functions Definitions Notes...
Page 350: ...Publication 900 UM007D EN E January 2011 6 10 Troubleshooting Error Indication Notes...
Page 406: ...Publication 900 UM007D EN E January 2011 D 8 Glossary Notes...