Parameter Adjustments & Application Considerations
4-31
Alarms During SP Ramp Operation
The operation of alarms during SP ramp operation depends on whether
alarms are configured to be based on the ramp set point or the target set point
(refer to the Figure 4.48). The set point to be used is configured in the Alarm
SP Selection parameter.
Figure 4.48
To Move to the Advanced
Setting Function Group
By default, the Advanced Setting function group is protected and you cannot
directly move to this function group. To move to this function group you must
first cancel the protection applied by the Protect function group in the Initial
Setting/Communications Protect parameter. Refer to page 4-33,
Using the Key
Protect Function Group
.
EXAMPLE
Operation Procedure: To Remove Protection and Move to the Advanced
Setting Function Group
1.
Press the
and
M
keys simultaneously for at least 3 seconds in the
Operation function group.
Alarm SP Selection = Ramp SP (Alarm Type: 1 (Upper/Lower Limits))
Alarm SP Selection = Target SP (Alarm Type: 1 (Upper/Lower Limits))
Temperature
Temperature
Time
Time
Alarm output ON
Alarm output ON
Alarm output ON
Alarm output ON
Summary of Contents for Allen-Bradley 900-TC16
Page 1: ...USER MANUAL Bulletin 900 TC8 900 TC16 900 TC32 Series B Temperature Controllers...
Page 2: ...2...
Page 72: ...Publication 900 UM007D EN E January 2011 3 2 Configuration Basic Operation Figure 3 3 900 TC32...
Page 136: ...Publication 900 UM007D EN E January 2011 3 66 Configuration Basic Operation Notes...
Page 340: ...Publication 900 UM007D EN E January 2011 5 112 Parameter Functions Definitions Notes...
Page 350: ...Publication 900 UM007D EN E January 2011 6 10 Troubleshooting Error Indication Notes...
Page 406: ...Publication 900 UM007D EN E January 2011 D 8 Glossary Notes...