Publication 900-UM007C-EN-E - January 2011
Preface
P-ix
Option Units
(Series B Controller Compatible— One Option Unit per Controller)
This unit provides communications event input etc. functionality.
Table P.I
Bulletin No.
Name
Function
Cat. No. (Series)
900-TC8
(Series B)
Communications Unit
RS-232C communications
➊
900-TC8232 (B)
➍
RS-485 communications
900-TC8COM(B)
➍
Event Input Unit
Event Input
➋
900-TC8EIM(A)
900-TC16
(Series B)
Communications and 1-Phase Heater Burnout Unit
and Heater Short
RS-485 communications with
single-phase heater burnout (open) and
heater short-circuit failure detection
➌
900-TC16NCOM(B)
➎➏
Event Input Unit with 1-Phase Heater Burnout and
Heater Short
Event Input with single-phase heater
burnout (open) and heater short-circuit
failure detection
➋➌
900-TC16NEIM(B)
➎
Event Input Unit
Event Input
➋
900-TC16NACEIM(B)
➎
Communications Unit
RS-485 communications
900-TCNACCOM(B)
➎➏
Communications and 3-Phase Heater Burnout and
Heater Short Unit
RS-485 communications with 3-phase
heater burnout (open) and heater
short-circuit failure detection
900-TC16NCOMP3(B)
➎➏
Communications and Second Voltage (SSR) Output
Unit
RS-485 communications and a second
voltage (SSR) output
900-TC16NCOMV2(B)
➎➏
1-Phase Heater Burnout and second voltage (SSR)
output
1-Phase Heater burnout (open) and
heater short-circuit failure detection
with a second control voltage (SSR)
output
900-TC16P1V2(B)
➎
➊
Enables direct RS-232 connection to personal computer using 900BuilderLite™ software. A Cat. No. 900-CP1X cable or equivalent is
also required.
➋
Provides two event inputs. Allows selecting up to 4 different pre-configured set points, controller Run/Stop or Auto/Manual mode,
from 2 external inputs.
➌
Heater burnout is not available for 0...20 or 4…20 mA analog output style 900-TC16 controllers such as the 900-TC16AC.
➍
To obtain 57.6 k baud rate, Series B communication units must be used with any Series A or Series B 900-TC8 controller catalog
number.
➎
Series B option units must be used with Series B 900-TC16 controllers. Series A option units cannot be used with Series B controllers
and vice versa.
➏
Series B provides 57.6 K baud rate.
Summary of Contents for Allen-Bradley 900-TC16
Page 1: ...USER MANUAL Bulletin 900 TC8 900 TC16 900 TC32 Series B Temperature Controllers...
Page 2: ...2...
Page 72: ...Publication 900 UM007D EN E January 2011 3 2 Configuration Basic Operation Figure 3 3 900 TC32...
Page 136: ...Publication 900 UM007D EN E January 2011 3 66 Configuration Basic Operation Notes...
Page 340: ...Publication 900 UM007D EN E January 2011 5 112 Parameter Functions Definitions Notes...
Page 350: ...Publication 900 UM007D EN E January 2011 6 10 Troubleshooting Error Indication Notes...
Page 406: ...Publication 900 UM007D EN E January 2011 D 8 Glossary Notes...