Publication 900-UM007D-EN-E - January 2011
B-16
Setup Function Group
Diagrams
This diagram shows all of the function groups. To move to the advanced
setting function group and calibration function group, you must enter
passwords. Some parameters are not displayed depending on the protect
function group configuration and the conditions of use.
Figure B.1 — All Function Groups
➊
You can return to the operation level by executing a software reset. When the PF Setting parameter is
crossovered to A-M for a Controller with a PF Key (900-TC8)
➋
It is not possible to move to other levels from the calibration level by operating the keys on the front
panel. It can be done only by first turning OFF the power. When the PF Setting parameter is configured to PFDP
for a Controller with a PF Key (900-TC8).
➌
From the manual control level, key operations can be used to move to the operation level only.
➍
When the PF Setting parameter is confingured to A-M for a Controller with a PF Key (900-TC8 only).
➎
When the PF Setting parameter is configured to PFDP for a Controller with a PF Key (900-TC8 only) From the
manual control function group, key operations can be used to move to the operation function group only.
Start in Manual Mode
25
100
c
25
100
c
a-m
Power ON
O
O
a-m
a-m
O
O
Input Password
amoV
O
O
Control Stops
O
O
M
Protect
Function Group
Control in Progress
Function Group Change
Not Displayed for Some Models
Control Stopped
Start in Automatic Mode
PF Key
O
M
Operation
Function Group
Adjustment
Function Group
Manual Control
Function Group
Manual
Mode
1
3
3
1
4
2
2
5
5
4
Press the Key or the
PF Key for at least 1 second.
Press the
Key for less than 1 second.
Monitor/Setting
Function Group
Press the PF Key
for at least 1 second.
Press the
Key for at
least 1 second.
Press the
Key for at
least 1 second.
Input the password
while is displayed.
(Set Value - 169)
Press the
Key for less than 1 second.
2
Press the Key for at
least 3 seconds.
(Display will flash after 1
st
second.)
Note:
The time taken to move
to the Protect level can
be adjusted by changing
the “Move to protect level
time” setting.
Communications
Setting
Function Group
Initial Setting
Function Group
Advanced Setting
Function Group
Calibration
Function Group
Protect the
+ Keys
for at least
1 second.
Protect the
+ Keys
for at least
3 seconds.
(Display will
flash after 1st
second.)
Press the Key for at
least 3 seconds while
is displayed. ( will
flash after 1
st
second.)
➊
Summary of Contents for Allen-Bradley 900-TC16
Page 1: ...USER MANUAL Bulletin 900 TC8 900 TC16 900 TC32 Series B Temperature Controllers...
Page 2: ...2...
Page 72: ...Publication 900 UM007D EN E January 2011 3 2 Configuration Basic Operation Figure 3 3 900 TC32...
Page 136: ...Publication 900 UM007D EN E January 2011 3 66 Configuration Basic Operation Notes...
Page 340: ...Publication 900 UM007D EN E January 2011 5 112 Parameter Functions Definitions Notes...
Page 350: ...Publication 900 UM007D EN E January 2011 6 10 Troubleshooting Error Indication Notes...
Page 406: ...Publication 900 UM007D EN E January 2011 D 8 Glossary Notes...