Calibration
C-11
3.
Turn the power ON.
4.
Move to the Calibration function group. This starts the 30-minute aging
timer. This timer provides an approximate timer for aging. After 30
minutes, the No. 2 display changes to 0. You can advance to the next
step in this procedure even if 0 is not displayed.
Figure C.17
5.
Press the
M
key to set the Bulletin 900 to the state below. The No. 2
display at this time displays the currently entered count value entered in
Hexadecimal. Set the STV to 54 mV.
Figure C.18
6.
Allow the count value on the No. 2 display to fully stabilize, then press
the
D
key to temporarily register the calibration settings.
If this count value is outside of the specified range, the No. 2 display will
flash and the count value will not be temporarily registered.
7.
Press the
M
key to set the Bulletin 900 to the state below. Set STV to
–6mV.
Figure C.19
8.
Allow the count value on the No. 2 display to fully stabilize, then press
the
D
key to temporarily register the calibration setup. If this count
value is outside of the specified range, the No. 2 display will flash and
the count value will not be temporarily registered.
9.
Press the
M
key. The No. 2 display changes to the state below. Note
that the data to be temporarily registered is not displayed when it is not
entirely prepared. Press the
U
key. The No. 2 display changes to
yes
.
Release the key and wait 2 seconds or press the
M
key. This stores the
temporarily registered calibration data to EEPROM. To cancel the
saving of temporarily registered calibration data to EEPROM, press the
M
key (while
no
is displayed in the No. 2 display) without pressing the
U
key.
adj
30
t
-
54
b9a5
t
-
-6
2988
Summary of Contents for Allen-Bradley 900-TC16
Page 1: ...USER MANUAL Bulletin 900 TC8 900 TC16 900 TC32 Series B Temperature Controllers...
Page 2: ...2...
Page 72: ...Publication 900 UM007D EN E January 2011 3 2 Configuration Basic Operation Figure 3 3 900 TC32...
Page 136: ...Publication 900 UM007D EN E January 2011 3 66 Configuration Basic Operation Notes...
Page 340: ...Publication 900 UM007D EN E January 2011 5 112 Parameter Functions Definitions Notes...
Page 350: ...Publication 900 UM007D EN E January 2011 6 10 Troubleshooting Error Indication Notes...
Page 406: ...Publication 900 UM007D EN E January 2011 D 8 Glossary Notes...