Rockwell Automation Publication 440G-UM001A-EN-P — November 2013
17
Installation and Wiring
Chapter 3
Mounting the Switch Body
Three M5 fasteners (not provided) are required for proper mounting to a
rigid guard door frame.
Setting Actuator to Switch
Alignment
There are three ways to achieve proper alignment.
1. By setting gap “G”
2.5 mm (0.09 in.) [0…5 mm (0…0.19 in.)]
2. By mounting hole alignment ”H”
6.5 mm (0.25 in.) [4…9 mm (0.15…0.35 in.)]
3. Using the alignment guide
provided
3
x
M5
G
H