42
Rockwell Automation Publication 440R-UM014D-EN-P - December 2019
Appendix A
Specifications
Power Supply (A1/A2)
Table 12 - Power Supply (A1/A2) Specifications
Inputs (L1/L2/L3)
Table 13 - Input (L1/L2/L3) Specifications
Safety Outputs
Table 14 - Safety Output Specifications
Status Outputs
Table 15 - Status Output Specifications
Attribute
DC
AC
AC
Power supply voltage, nominal
24V DC
PELV, Class 2
115V AC
230V AC
Voltage range
0.9…1.2
0.8…1.1
Power consumption [DC: W, AC: VA]
3
5
Frequency range [Hz]
—
45…60
Ripple, max [%]
10
—
Fuse, slow blow [A]
2
Start-up delay [s]
0.8 + t
s
Attribute
Value
Motor voltage, max [V AC]
690 (UL 600)
Input resistance [k
Ω
]
500
Monitoring trip value
[mV]
[V]
20… 400, adjustable
0.2…4, adjustable
Response value dependent on frequency
Input frequency [Hz]
50
100
200
400
600
1000
1500
2000
Multiplication factor for V
m
1.0
1.1
1.2
1.5
2.0
2.8
5.0
8.0
Hysteresis for detection of running
motor [%]
100
Release delay for detection of running
motor [ms]
<100
Standstill time delay, t
s
[s]
0.2…6, adjustable
Attribute
Value
Wiring terminals
23/24, 33/34, 43/44 redundant, positive guided, normally open
11/12 redundant, positive guided, normally closed
Switching
capacity
UL rating at
40 °C (104 °F)
Pilot Duty B300, 5 A @ 250V AC, 5 A @ 24V DC
UL rating at
60 °C (140 °F)
Pilot Duty B300, 2 A @ 250V AC, 2 A @ 24V DC
AC15
N.O.: 3 A @ 230V AC, N.C.: 1 A @ 230V AC
DC13
N.O.: 1 A @ 24V DC, N.C.: 1 A @ 24V DC
DC13 at 0.1 Hz
N.O.: 4 A @ 24V DC, N.C.: 4 A @ 24V DC
Thermal current, up to 40 °C (104 °F) [A]
5
Fusing external, max
4AgL fuse or C6A circuit breaker
Operating frequency, max [ops/hr]
1200
Contact life at load [switching cycles]
at 5 A 230V AC, cos
φ
=1
≥200,000
Mechanical life at no load
[switching cycles]
≥50,000,000
Attribute
Value
A3/A4 power supply voltage range [V DC]
12…30 PELV/SELV or Class 2
Power consumption [W]
3
ON, ERR max current at 24V DC [mA]
100
53/54 contact rating [A/VAC]
3/250