Rockwell Automation Publication 2071-UM001E-EN-P - November 2013
47
Kinetix 3 Drive Connector Data
Chapter 3
Analog Inputs
The Kinetix 3 drive has two single-ended analog inputs. One is dedicated as the
command input for Analog Velocity mode, and the second is dedicated as the
command input for Analog Current mode.
shows the configuration of
the analog input.
Figure 21 - Analog Input Configuration
This table provides a description of the analog input specifications.
VCMD
-12V
+12V
GND
2.5V REF
GND
10 nF
GND
VCC
V_REF
GND
T_REF
GND
VCC
GND
GND
2.5V REF
GND
+12V
-12V
ICMD
Parameter
Description
Min
Max
VCMD
Resolution
Number of states that the input signal is divided into,
[2
(to the number of bits)
].
16 bits
—
ICMD
Resolution
12 bits
—
Input
Impedance
Open circuit impedance measured between the positive (+)
input and analog common.
10 kΩ
—
Input Signal
Range
Voltage applied to the input.
-10V
+10V