Rockwell Automation Publication 2071-UM001E-EN-P - November 2013
49
Kinetix 3 Drive Connector Data
Chapter 3
Figure 22 - Analog Output Configuration
This table provides a description of the analog output specifications.
GND
GND
MP
LM224
LM224
VCC
A_MON
IMPORTANT
Output values can vary during powerup until the specified power supply
voltage is reached.
Parameter
Description
Min
Max
Resolution
Number of states that the output signal is divided into,
2
(to the number of bits)
.
12 Bits
—
Output Current
Current capability of the output.
-10 mA
+10 mA
Output Signal
Range
Range of the output voltage.
-10V
+10V