Rockwell Automation Publication 2198-RM003A-EN-P - February 2020
19
Replacement Considerations
Chapter 2
Power Specifications
This section lists the power specifications for the Ultra3000 drive and
Kinetix 5100 drives.
shows power specifications and requirements for
the Ultra3000 230V drives.
Table 12 - Ultra3000 Servo Drive Power Specifications
Attribute
2098-DSD-005
2098-DSD-010
2098-DSD-020
2098-DSD-030
2098-DSD-075
2098-DSD-150
AC Input Voltage
(1)
100…240V rms, 1 PH
100…240V rms,
1 PH
100…240V rms, 3 PH
AC Input Frequency
47…63 Hz
47…63 Hz
AC Input Current
(2)
(3)
rms (nom)
230V AC (0-PK) max inrush
(4)
5 A
100 A - Series A or B
20 A - Series C
9 A
100 A - Series A or B
20 A - Series C
18 A
100 A - Series A or
B
20 A - Series C
28 A
50 A
30 A
50 A
46 A
68 A
Auxiliary AC input current
115V AC (rms) nom
230VV AC (rms) nom
115V AC (0-pk) max inrush(4)
230V AC (0-pk) max inrush
—
—
—
1.0 A
0.5 A
47 A
95 A
1.0 A
0.5 A
47 A
95 A
1.0 A
0.5 A
47 A
95 A
Continuous output current (rms)
1.8 A
3.5 A
7.1 A
10.6 A
24.7 A
45.9 A
Continuous output current (0-pk) 2.5 A
5.0 A
10 A
15 A
35 A
65 A
Peak output current (rms)
5.3 A
10.6 A
21.2 A
21.2 A
53 A
106 A
Peak output current (0-Pk)
7.5 A
15 A
30 A
30 A
75 A
150 A
Bus Capacitance
1410 μF
1880 μF
1880 μF
2820 μF
4290 μF
7520 μF
Internal Shunt resistance
—
—
—
35 ohms
16.5 ohms
9.1 ohms
Shunt on
—
—
—
420V DC
Shunt off
—
—
—
420V DC
Bus Overvoltage
400V DC
452V DC
Internal shunt
Continuous power
Peak power
—
—
—
50 W
4.5 W
50 W
10 kW
180 W
18 kW
External shunt
Resistance
Continuous power
Peak power
—
—
—
30 ohms (-0/+5%)
2.4 kW
6 kW
16.5 ohms (-0/
+5%)
4 kW
10 kW
9 ohms (-0/+5%)
8 kW
19 kW
Energy absorption capability
115V AC input
230V AC input
93 J
38 J
125 J
51 J
251 J
139 J
381 J
211 J
669 J
370 J
Continuous power output
115V AC input
230V AC input
0.25 kW
0.5 kW
0.5 kW
1.0 kW
1.0 kW
2.0 kW
1.5 kW
3 kW
—
7.5 kW
—
15 kW
(1) Specification is for nominal voltage. The absolute limits are ± 10%, or 88…265V rms.
(2) The 2098-DSD-005
x-xx
, 2098-DSD-010
x-xx
(200V - class) drives are limited to:
Series A or B - one contactor cycle every two minutes.
Series C - one contactor cycle every 10 s for up to two minutes, not to exceed 12 cycles in five minutes.
(3) Power initialization requires a short period of inrush current. Dual element time delay (slow blow) fuses are recommended.
(4) Inrush current limiting circuitry is enabled within 3 s after removal of AC line power.