Publication 2094-UM001A-EN-P — September 2006
160
Troubleshooting the Kinetix 6000 Drive System
Supplemental
Troubleshooting
Information
This section provides information for accessing and changing
parameters not accessible through RSLogix 5000 software.
Tools for Changing Parameters
Most parameters are accessible through RSLogix 5000 software.
Alternatives include the DPI compatible Human Interface Module
(HIM) and DriveExplorer software.
Changing Parameters Using DriveExplorer
To navigate using DriveExplorer, refer to the example dialog below.
In this example, the I/O Interface group folder is open, the Analog
Outputs parameter is selected, and the parameter elements are
displayed in the box to the right.
DriveExplorer Example
Method
Description
Catalog Number
Firmware Revision
DriveExplorer
DriveExplorer software
(1)
9306-4EXP02ENE
2.01 or later
Serial to SCANport adapter
1203-SSS (Series B)
3.004 or later
HIM
Full numeric LCD HIM
20-HIM-A3
(2)
N/A
(1)
Refer to DriveExplorer Getting Results Manual, publication 9306-GR001, for instructions.
(2)
Compatible catalog numbers include all 20-HIM-A
x
.
IMPORTANT
Parameters are read-only when the SERCOS ring is active. You
must break the SERCOS ring to change parameters.
To save changes, perform a non-volatile save (NVS) prior to
cycling power.
Summary of Contents for Allen-Bradley Kinetix 6000
Page 8: ...Publication 2094 UM001A EN P September 2006 8 Table of Contents...
Page 18: ...Publication 2094 UM001A EN P September 2006 18 Start...
Page 118: ...Publication 2094 UM001A EN P September 2006 118 Connecting the Kinetix 6000 Drive System...
Page 190: ...Publication 2094 UM001A EN P September 2006 190 Specifications and Dimensions...
Page 265: ...Publication 2094 UM001A EN P September 2006 265 Notes...
Page 266: ...Publication 2094 UM001A EN P September 2006 266 Notes...
Page 267: ...Publication 2094 UM001A EN P September 2006 267 Notes...