Publication 2094-UM001A-EN-P — September 2006
Specifications and Dimensions
179
Contactor Ratings
The table below lists the recommended contactor ratings for
integrated axis modules installed without a line interface module.
Transformer Specifications for Control Power Input
Catalog Number
230V IAM
Contactor
Catalog Number
460V IAM
Contactor
2094-AC05-MP5-S
100-C23x10 (ac coil)
100-C23Zx10 (dc coil)
2094-BC01-MP5-S
100-C23x10 (ac coil)
100-C23Zx10 (dc coil)
2094-AC05-M01-S
2094-BC01-M01-S
2094-AC09-M02-S
100-C37x10 (ac coil)
100-C37Zx10 (dc coil)
2094-BC02-M02-S
100-C37x10 (ac coil)
100-C37Zx10 (dc coil)
2094-AC16-M03-S
100-C72x10 (ac coil)
100-C72Zx10 (dc coil)
2094-BC04-M03-S
100-C60x10 (ac coil)
100-C60Zx10 (dc coil)
2094-AC32-M05-S
100-C85x10 (ac coil)
100-C85Zx10 (dc coil)
2094-BC07-M05-S
100-C72x10 (ac coil)
100-C72Zx10 (dc coil)
Attribute
Value (460V system)
Input volt-amperes
750VA
Input voltage
460V ac
Output voltage
120...240V ac