Publication 2094-UM001A-EN-P — September 2006
236
DC Common Bus Applications
Setting the Additional Bus Capacitance Parameter
Follow these steps to set the Additional Bus Capacitance parameter.
1.
Start your DriveExplorer software.
2.
From the menu bar choose Explore\Connect\Local or enter Ctrl-L
from the keyboard.
DriveExplorer software will read your system.
3.
Observe the Linear List of parameters as grouped by Node, Port,
and Axis hierarchy as shown below.
4.
Select Devices\Node\Product\ and navigate to the parameter
x:x:x
599 as shown below.
5.
Double-click the
x:x:x
599 Add Bus Cap parameter.
N: P.
x xxx
Network Node Number
DPI Port Number
Parameter Number
30 = Version Data
Linear List Legend
Axis Number
0 = IAM (axis 1)
1 = AM (axis 2)
2 = AM (axis 3)
3 = AM (axis 4)