Rockwell Automation Publication 2711T-QS002C-EN-P - March 2019
25
Second Generation MobileView Tethered Operator Terminal
c. After 10 seconds of disconnect time, verify that all six lights of the status indicator
bar are off and subsequently replaced by a blinking yellow status indicator bar.
The blinking yellow status indicates that the relay outputs of the IP65 junction box
are de-energized and therefore open, which triggers an emergency stop of the system
or machine.
IP65 Junction Box Status Indicator Lights
The front of each IP65 junction box has three status indicators and a status indicator bar.
explains what each color signifies on the lights and status indicator bar.
IMPORTANT
Only perform step c if you are commissioning the unit, performing
maintenance, or testing safety equipment, because step c triggers a system
emergency stop.
WARNING:
An IP65 junction box does not protect against the restart of a system or
machine. Separate protection must be provided on the system or machine, such as
an Acknowledgment key.
Table 2 - IP65 Junction Box Status Indicators and Bar Colors
Indicator
Color Displayed
Status Indicated
Power
Green
Power is present and the IP65 junction box is ready for operation.
No color
No power is present or there is a fault during startup.
Illuminated
E-stop
Green
A second generation MobileView terminal with an illuminated E-stop button is connected
to the junction box.
No color
A second generation MobileView terminal without an illuminated E-stop button is
connected to the junction box.
Power
Illuminated
E-stop
Status Indicator
Bar
Ethernet