MP-Series Heavy Duty Electric Cylinders
57
Rockwell Automation Publication MPAI-IN001E-EN-P - March 2012
12.
Apply medium strength thread-locker to the anti-rotate shaft fastener and assemble
through the anti-rotate clamp and into the anti-rotate shaft; torque to the value shown
on the table.
13.
Torque the two bearing block fasteners as shown in the table.
14.
Use the procedure in
Configure Your Servo Drive with RSLogix 5000 Software on
Frame Size
Torque
64
7.8 N•m (5.75 lb•ft)
83
110
144
20.3 N•m (15.0 lb•ft)
Frame Size
Torque
64
13.2 N•m (9.7 lb•ft)
83
39.5 N•m (29.13 lb•ft)
110
144
56.5 N•m (70.0 lb•ft)