Rockwell Automation Publication 6200-UM001C-EN-P - July 2018
31
Install the Thin Client or Computer
Chapter 3
6. Apply 24V DC power to the thin client or computer.
AC Power Options
The following options are available to connect AC to 24V DC power for
VersaView 5000 thin clients or industrial computers, except for the
6200T-BA thin client single display model
(1)
. These options must be ordered
separately.
• An AC to 90 W, 24V DC power adapter and power cord
(cat. no. 6200V-MPS4)
(2)
• An AC to 40 W, 24V DC power adapter and power cord
(cat. no. 6200V-MPS6)
(2)
• Allen-Bradley® switched mode power supplies:
https://ab.rockwellautomation.com/Power-Supplies/Switched-Mode-
Power-Supplies
Both power adapters ship with a power cord that has an IEC 60320 C14
receptacle and a standard NEMA 5-15P three-prong plug for use in North
America. Any IEC 60320 C13 power cord can be used for other international
applications.
Follow these steps to connect a separately purchased AC to DC power adapter
to an AC power source.
1. Connect the AC to DC power adapter to the DC power input on the
computer. See Hardware Features on
for the DC
power input location.
2. Connect the receptacle end of the power cord to the power adapter.
3. Connect the three-prong plug end of the power cord to an AC power
source.
TIP
Integrated display thin clients and computers have a ground stud
on the computer base. See
for its location.
On non-display thin clients and
computers with bookshelf
mounting brackets, a ground screw
is on one end of the bracket, as
shown at right.
Use this ground screw to connect
the thin client or computer to earth ground.
(1) The 6200T-BA thin client model is supplied with an AC to 5V DC power adapter and cord. To order a replacement, see
Connect Peripherals on page 28
.
(2) See
Connect Peripherals on page 28
for which VersaView models work with each power adapter.
SHOCK HAZARD:
Connect the power cord to an AC power source with
an earth ground. Failure to follow this warning can result in electrical