MSR127RP/TP
Description
The MSR127RTP can be connected in three different input wiring configurations: one normally closed, two normally closed, or with
two PNP connections from a light curtain. When connected in the two normally closed fashion, the MSR127RTP checks for cross faults
across the two inputs. When connected to light curtains, the light curtain must perform the cross fault detection.
The MSR127RP has a monitored manual reset. The MSR127TP has an automatic/manual reset. Models with automatic/manual reset
can have the reset jumpered or can be converted to an unmonitored manual reset by adding a normally open switch in the monitoring
loop. Models with monitored manual reset provide checking of the output monitoring circuit.
The outputs include three normally open safety-rated outputs as well as one normally closed auxiliary output. The safety outputs have
independent and redundant internal contacts to support the safety function. The auxiliary output is a nonsafety output intended to
provide an external signal about the status of the safety outputs.
Features
Category 4 per EN 954-1
Stop category 0
Three safety contacts
One auxiliary contact
Cross fault monitoring
Monitored or automatic reset
Removable terminals
Light curtain, E-stop or safety gate applications
LED Indicators
Green
Power On
Green
CH1 Closed
Green
CH2 Closed
Specifications